<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-23 07-25-12
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 70 dBuV ISKELMA
Pilot RDS Phase Difference
6.5 kHz 2.8 kHz -85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19079 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 5,24 dBr 6,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2024/10/23 7.24.08 Total samples: 19079 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 6,8 dBr MIN: 3,5 dBr AVE: 5,24 dBr % above 12,2 dBr: 0,0 Last value: 3,7 dBr (2024/10/23 7.24.07) 07.10 07.12 07.14 07.16 07.18 07.20 07.22 07.24 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]